Adaptación de lentes de contacto en 133 ojos con astigmatismo irregular

  1. A. Galindo-Ferreiro
  2. J. Galindo-Alonso
  3. H. Sánchez-Tocino
  4. J. Palencia-Ercilla
Revista:
Archivos de la Sociedad Española de Oftalmologia

ISSN: 0365-6691

Any de publicació: 2007

Volum: 82

Número: 12

Pàgines: 747-751

Tipus: Article

DOI: 10.4321/S0365-66912007001200006 DIALNET GOOGLE SCHOLAR lock_openAccés obert editor

Altres publicacions en: Archivos de la Sociedad Española de Oftalmologia

Objetivos de desarrollo sostenible

Resum

Purpose: To study the adaptation of contact lens in a sample of 133 eyes with irregular astigmatism. Methods: A retrospective study was made in 133 eyes with irregular astigmatism. The selection criterion was to obtain a sample population with irregular astigmatism that was unlikely to be corrected with spectacles or conventional contact lens. A complete ophthalmologic exploration which included a topography with the Eye-Sys 2000 corneal topographer was made was made. The variables analyzed in the study were: refraction, visual acuity before and after the correction, cause of the astigmatism and contact lens used. Results: An equal number of women and men were enrolled in the study. The right eye was studied in 52% of cases, and the left eye in 46%. Both eyes were affected in 67% of the subjects. The reason for the astigmatism was keratoconus in 110 eyes (78.2%), and there were 4 corneal injuries, 9 ocular infections, and 6 idiopathic astigmatisms. Among the contact lens used in the study: in 103 eyes a hybrid lens (Softperm®) was adapted, in 20 eyes a piggy-back system, in 5 eyes a thick hydrophilic lens (Queratosoft®), in 4 eyes a hydrophilic contact lens and in 3 cases a rigid gas permeable contact lens. The average visual acuity before the adaptation was 0.28 (SD 0.24) (range 0.1-0.8). After the use of the lens the average visual acuity was 0.81 (SD 0.23) (range 0.1-1). Statistically significant differences between the visual acuity before and after treatment were found, with an improvement of 0.53 (SD 0.28) obtained. Conclusion: Only with experience using a large variety of non-conventional contact lens can a specialist contact lens ophthalmologist achieve a good result.

Referències bibliogràfiques

  • Ridley, F. (1956). Contact lenses in treatment of keratoconnus. Br J Ophthalmol. 40. 295-304
  • Smiddy, WE, Hamburg, TR, Kracher, GP, Stark, WJ. (1988). Keratoconus: Contact lens or keratoplasty?. Ophthalmology. 95. 487-492
  • Yeung, K, Eghbali, F, Weissman, BA. (1995). Clinical experience with piggyback lens systems on keratoconic eyes. J Am Optom Assoc. 66. 539-543
  • Lim, N, Vogt, U. (2002). Characteristics and functional outcomes of 130 patients with keratoconus attending a specialist contact lens clinic. Eye. 16. 54-59
  • Maguen, E, Caroline, P, Rosner, IR, Macy, JI, Nesburn, AB. (1992). The use of the Softperm lens for the correction of irregular astigmatism. CLAO. 1823. 173-176
  • O'Donnell, C, Maldonado-Codina, C. (2004). A hiperDK piggyback contact lens system for keratoconus. Eye Contact Lens. 30. 44-48
  • Lass, JH, Lembach, RG, Park, SB, Hom, DL, Fritz, ME, Svilar, GM. (1990). Clinical management of keratoconus: A multicenter analysis. Ophthalmology. 97. 433-445
  • Mehta, M, Bhagwanjee, A, Hilliar, O. (2006). A clinical and optical evaluation of a modified lens for irregular cornea. Clin Exp Optom. 89. 30-36
  • Titiyal, JS, Sinha, R, Sharma, N, Sreenivas, V, Vajpayee, RB. (2006). Contact lens rehabilitation following repaired corneal perforations. BMC Ophthalmol. 14. 11
  • Gruenauer-Kloevekom, C, Kloevekom-Fischer, U, Duncker, GI. (2005). Contact lenses and special back surface design after penetrating keratoplasty to improve contact lens fit and visual outcome. Br J Ophthalmol. 89. 1601-1608
  • González-Méijome, J, De Almeida, JB, Parafita, MA. (2006). Soft contact lenses for keratoconus: case report. Eye Contact Lens. 32. 143-147