Electronic Health Records in a Tele-Ophthalmologic Application with Oracle 10g

  1. de la Torre Díez, Isabel 1
  2. Sánchez, Roberto Hornero 1
  3. Coronado, Miguel López 1
  4. López Gálvez, María Isabel 1
  1. 1 University of Valladolid, Spain
Libro:
Biocomputation and Biomedical Informatics

ISSN: 2327-7033 2327-7041

Año de publicación: 2010

Páginas: 89-105

Tipo: Capítulo de Libro

DOI: 10.4018/978-1-60566-768-3.CH005 GOOGLE SCHOLAR lock_openAcceso abierto editor

Resumen

Electronic health record (EHR) refers to the complete set of information that resides in electronic form and is related to the past, present and future health status. EHR standardization is a key characteristic to exchange healthcare information. Health Level Seven (HL7) and Digital Imaging and Communications in Medicine (DICOM) are intensively influencing this process. This chapter describes the development and experience of a web-based application, TeleOftalWeb 3.2, to store and exchange EHRs in ophthalmology. We apply HL7 Clinical Document Architecture (CDA) and DICOM standards. The application has been built on Java Servlet and Java Server Pages (JSP) technologies. EHRs are stored in the database Oracle 10g. Its architecture is triple-layered. Physicians can view, modify and store all type of medical images. For security, all data transmissions were carried over encrypted Internet connections such as Secure Sockets Layer (SSL) and HyperText Transfer Protocol over SSL (HTTPS). The application verifies the standards related to privacy and confidentiality. TeleOftalWeb 3.2 has been tested by ophthalmologists from the University Institute of Applied Ophthalmobiology (IOBA), Spain. Nowadays, more than thousand health records have been introduced.

Referencias bibliográficas

  • 10.1109/TITB.2005.847159
  • Bott, O. J. (2004). Electronic Health Record: Standardization and Implementation. In 2nd OpenECG Workshop, Berlin, Germany, (pp. 57-60).
  • Brooke, J. (1996). SUS: a “quick and dirty” usability scale.
  • R.Chen, (2007), BMC Medical Informatics and Decision Making, pp. 7
  • S. J.Chew, (1998), HKMJ, 4, pp. 300
  • 10.1109/TITB.2006.874201
  • Chronaki, E., Lelis, P., Demou, C., Tsiknakis, M., & Orphanoudakis, S. C. (2001). An HL7/CDA framework for the design and deployment of Telemedicine services. Proceedings of the 23rd Annual EMBS International Conference, October 25-28, Istanbul, Turkey, (pp. 3504-3507).
  • 10.1046/j.1442-9071.2000.00309.x
  • 10.1197/jamia.M1888
  • M.Eichelberg, (2005), ACM Computing Surveys, 5, pp. 1
  • 10.1049/cce:20050505
  • I.Fedyukin, (2002), Ehealth International, 1, pp. 1
  • 10.1109/TITB.2006.879588
  • 10.1377/hlthaff.24.5.1323
  • Ginsburg, M. (2007). Pediatric Electronic Health Record Interface Design: The PedOne System. In Proceedings of the 40th Hawaii International Conference on System Sciences, (pp. 1-10).
  • Gurley, L. (2004). Advantages and disadvantages of the Electronic Medical Record. Des Plaines, IL: American Academy of Medical Administrators.
  • 10.1016/S1386-5056(98)00095-1
  • Hansen, I. B. (2006). CipherMe: personal Electronic Health Records in the hands of patients-owners. Proceedings of the 1st Distributed Diagnosis and Home Healthcare (D2H2) Conference, (pp. 148-151).
  • Health Level 7, HL7. (2000). ANSI Standard HL7 V 2.4-2000.
  • HIMSS Electronic Health Record Committee. (2003). EHR Definition, Attributes and Essential Requirement.
  • 10.1109/4233.767083
  • 10.1109/4233.788578
  • IEEE Computer Society (1993). IEEE Recommended Practice for Software Requirements Specifications, Std. 830.
  • 10.1109/4233.908366
  • 10.1258/135763307781645086
  • Kim, E. H. (2006). Web-based Personal-Centered Electronic Health Record for Elderly Population. In Proceedings of the 1st Distributed Diagnosis and Home Healthcare (D2H2) Conference, (pp. 144-147).
  • Klein,J.(2005). Integrating Electronic Health Records Using HL7 Clinical Document Architecture.
  • P. M.Kuzmak, (2000), Digital Imaging, 13, pp. 133, 10.1007/BF03167644
  • 10.1117/12.480668
  • 10.1034/j.1600-0420.2003.00045.x
  • 10.1197/jamia.M2318
  • 10.1197/jamia.M1375
  • 10.1109/CIC.2004.1443014
  • 10.1109/CIC.2003.1291168
  • 10.1136/bjo.83.11.1254
  • National Eye Institute [Online]. (2007). Retrieved from http://www.nei.nih.gov.
  • NEMA. (2000). Digital Imaging and Communications in Medicine (DICOM): Version 3.0. Hornero, R., López, M.I., Acebes, M. and Calonge, T. (2003). Teleophthalmology for diabetic retinopathy screening in a rural area of Spain, Eighth Annual Meeting of the American Telemedicine Association (ATA’2003).
  • Oracle Database Online Documentation 10g Release 2 [Online]. (2007). Retrieved from http://youngcow.net/doc/oracle10g/index.htm.
  • Paterson, G. I., Shepherd, M., & Wang, X. Watters, C. & Zitner, D. (2002). Using the XML-based Clinical Document Architecture for Exchange of Structured Discharge Summaries. In Proceedings of the 35th Hawaii International Conference on System Sciences, (pp. 119-128).
  • Pawson, D. (2002). XSL-FO Making XML Look Good in Print.
  • D.Smith, (2002), Journal of Healthcare Information Management, 16, pp. 71
  • Xiang, Y., Gu, Q., & Li, Z. (2003). A Distributed Framework of Web-based Telemedicine System. In Proceedings of the 16th IEEE Symposium on Computer-Based Medical Systems, (pp. 108-113).
  • 10.1111/j.1442-9071.1998.tb01385.x